Installation, Wiring, Plumbing – TFC Group A3MID User Manual

Page 2: Specifications, Tfc group ltd, Grey, Orange, Blue, Green & yellow, All dimensions in mm port ab

Advertising
background image

INSTALLATION INSTRUCTIONS

MID-POSITION VALVE VAL322MP VAL328MP

INSTALLATION

Before fitting the valve, read through the plumbing
and wiring instructions. When replacing the valve
actuator only, set the Auto/Manual lever to the
“Manual Open” position before removal. On the
replacement actuator set the Auto/Manual lever to
“Manual Open” position before fitting.

WIRING

All wiring should be carried out to IEE Regulations

White

-

Room Thermostat Call / Heating on

Grey

-

Cylinder Thermostat Sat / Hot water off

Orange

-

Cylinder Thermostat Call / Boiler and Pump

Blue

-

Neutral

Green & Yellow -

Earth

PLUMBING

When connecting to pipe work do not use the
actuator for leverage. Valves should be held by
wrench flats on body. Place the AUTO/MAN lever
in the MAN position when filling, venting or draining
the system.

TAKE CARE NOT TO OVERTIGHTEN

SPECIFICATIONS

• Supply voltage 240V. AC 50Hz

• Power consumption: 6W
• Operating temperature range: +5 to +88

0

C

• Cable length one metre

• Max. differential pressure for 22mm = 1Bar

• Max. static pressure 10.0 Bar

• Max. ambient temperature 52

0

C

MOUNTING OPTIONS
Valves may be mounted vertically, or horizontally within
the limits shown in the diagram.

WARNING
All controls must be earthed. All valves should have a
means of disconnection from electrical mains supply
which incorporates a contact separation of at least 3mm
in all Poles.

All wiring must be carried out by a competent
Electrician.

TFC GROUP LTD

Tower House, Vale Rise, Tonbridge, Kent, TN9 1TB, Telephone: 01732 359888 Fax: 01732 354445

88

60

55

55

43.5

122

93

All dimensions in MM

Port AB =

Pumped flow from boiler

Port A =

Heating circuit

Port B =

Domestic hot water circuit

A

B

AB

Mid - position Valve

Typical circuit showing Programmer, Room and Cylinder Thermostats as control elements

PROGRAMMER

HEATING H,WATER

L N

ON

OFF

OFF ON

INCLUDE IF PROGRAMMER HAS A

HEATING ONLY SELECTION

240V AC 50Hz

Supply fused

At 3A

COM

SAT

CALL

ROOM

THERMOSTAT

COM

CALL SAT

CYLINDER

THERMOSTAT

TO BOILER & PUMP

VALVE

GRN /

Y

L

O

BL

UE

WH

IT

E

OR

A

N

GE

GRE

Y

45

0

45

0

VAL322MP and VAL328MP are 3 port spring return mid-position valves with 22mm and 28mm
compression fittings and switched output. These are for use on fully pumped systems which
when correctly wired with an appropriate room thermostat, cylinder thermostat and programmer
will control the water flow from the boiler to either to hot water only, heating only, or to both
simultaneously.