8 Specification

Preamps

A & B

Compressor

Input Impedance

Mic Lo
Mic Hi
Line

600Ω

1200Ω

10kΩ

N/A
N/A

10kΩ

Output Impedance

<400Ω <600

MOL (into 10kΩ)

+26dBu +26dBu

Distortion (1kHz)

0.1% 0.02%

*

Frequency Response
+0/-1 dB

<10-35kHz 13-80kHz

Total Noise (unweighted
30kHz filter) below MOL

103dB 105dB

Max Gain

34dB 28dB

Phantom Power

+48V N/A


* Increases with compression to a typical figure of 0.2% with
6dB compression.

The Nightingale can be set to operate from either 230V or
115V 50/60 Hz AC. The appropriate mains input voltage can
be selected on the red switch located next to the mains inlet.

Note: Mains fuses must be replaced in accordance with the
following table.

Mains Voltage

Fuse Rating

230V T315mA
115V T630mA