8

5

Servicing & Maintenance

5.1 Valves

All valves are selected to ensure that the unit gives
optimum and consistent performance across both
channels.

Although Thermionic Culture Ltd. guarantees the valves for
twelve months, they can last for up to twenty years.

Spares can be obtained from Thermionic Culture Ltd.

Valve complement:

Input -

2 x EF86;

Distortion - 2 x 6AS6;
Output -

5963 (12AU7 / ECC82 near equivalent)


5.2 Operating voltage / Fuse

The Culture Vulture is switch selectable to operate from
either 230V or 115V 50/60Hz AC mains supply.

NOTE: Mains fuses may be replaced in accordance with
the following table:

Operating Voltage

Fuse Rating

115V

T500mA 20mm type

230V

T250mA 20mm type