Error messages and troubleshooting guide – TrakPower VR-1 Dual Racing Charger User Manual

Page 23

Advertising
background image

23

Error Messages and Troubleshooting Guide

Several safety features are included in this charger to protect itself and the battery against
certain unwanted conditions, as follows:

No Battery

A battery is not connected to the output. Please connect the battery
to the output then restart.

Reverse Polarity

A battery is connected to the output in reverse! Please correctly
connect the battery to the output.

Input Voltage

The present input voltage is _.__V. Please check the input voltage.
The input voltage must be 11-15V.

Short-circuited

Output short circuited. Please check the output.

Low Output Voltage

Output voltage is lower than the selected cells or voltages.

Open Circuit

A battery is disconnected during an operation. Please reconnect the
battery and restart.

Temperature Sensor

A temperature sensor is connected in reverse or is defective.

Bat. Temp Too Low

Battery temperature is too low to be operated (the temperature
and output voltage will be displayed on the screen).

High Output Voltage

Output voltage is higher than the selected cells or voltages.

Internal Temp

Internal temperature is too hot! Contact Hobby Services if this
message appears often.

Data Communication

Something is wrong with the internal circuit. Contact Hobby Services.

Bat. Temp too High

Battery temperature is too high to be operated (The temperature
and output voltage will be displayed on the screen).

Bal. Voltage Low

Balancer cells voltage is too low!! The low cell number and voltage
will be displayed on the screen during this error.

Calibration Data

Either calibration data or internal circuit might have been damaged.

Bal. Voltage High

Balancer cells voltage is too high!! The high cell number and
voltage will be displayed on the screen during this error.

No Temp. Sensor

A temp-sensor is not connected to the port. Please connect the
temp-sensor to the port and restart.

Connection

Selected cells and cells connected to the balancing port are
different. Please re-check and re-start.

LCD MESSAGE

PROBLEM AND SOLUTION