Tube Tech CM1A Comp User Manual

Page 5

Advertising
background image

LYDKRAFT ApS

Mose Allé 20, DK 2610 Rødovre

Denmark

5

ADJUSTMENT PROCEDURE:

CAUTION:

Before making any adjustment let the unit heat-up at least 15 min.
Observe that the offset-voltage measured at the side chain jack socket, when the
THRESHOLD is off, is not greater than +/- 15 mV DC in both position "fixed" and
"manual".
(Tip is bus 1 and ring is bus 2).


If the voltage exceeds this value, replace either U1 or U2.

THE GRE SHALL BE MARKED BETWEEN 0.800-1.000



ADJUSTMENT OF BASIC GAIN:


1)

Apply a signal of 1 kHz, -30,0 dBU into the input of the compressor.


2)

Turn the GAIN-control fully clockwise.


3)

Set the RATIO-control at 2:1


4)

Adjust the pre-set GAIN (located on amp/psu PCB) to an output-reading of 0,0 dBU.




ADJUSTMENT OF COMPRESSION TRACKING
:

1)

Turn the THRESHOLD-control fully counter-clockwise.


2)

Set the RATIO-control at 2:1.


3)

Set the BUS-select-switch at 1.


4)

Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor.


5)

Adjust the GAIN-control to an output-reading of 0,0 dBU.


6)

Apply a DC-voltage of +250,0 mV into the side chain jack socket (tip) and observe that
the output level has dropped to -10,0 dB.


7)

If this is not the case, adjust the level with P 7, to obtain a drop of exactly -10,0 dB.






(

071221)