ADJUSTMENT OF THE VU METER READING "COMPRESSION":

(980112)

1) Turn the THRESHOLD-control fully counter-clockwise.

2) Switch the METER-selector to Compression.

3) Set the RATIO-control at 2:1

4) Apply a signal of 1 kHz, -20,0 dBU into the input.

5) Adjust the OUTPUTGAIN-control to an output-reading of 0,0 dBU.

6) Adjust P 14 until the meter is reading 0 VU.

7) Apply a DC-voltage of +250,0 mV into the side chain jack socket and observe that

the output level has dropped to -10,0 dBU. If this is not the case, adjust the
compression tracking (see above)

8) Adjust P 13 until the meter is reading -10,0 VU.

9) Remove the DC-voltage from the side chain jack socket (by setting the bus select

switch in the neutral position).

10) Repeat step 6 - 9.

NB: The VU-meter accuracy should be within +/- 0,5 dB when reading compression.