HIGH BAND:

1) Turn all the THRESHOLD-controls fully counter-clockwise.

2) Turn the HIGH BAND GAIN-control fully clockwise.

3) Turn the LOW BAND and MID BAND GAIN-control fully counter clockwise.

4) Set the X-OVER HIGH at 1,2k.

5) Apply a signal of 10 kHz, (approx. -20 dBU) to the input and adjust the input level

for an output reading of 0,0dBU.

6)

Move

t

he

j

umper

on

t

he

hi

gh

band

si

de

chai

n

PCB

(

t

op

most

PCB)

t

o

ADJUST”

and observe that the output level has dropped to -10,0 dBU.

7) If this is not the case, adjust the gain reduction with P61, to obtain a drop of -10,0 dB.

10) Adjust the high band display with P62 so the green -10 LED turns on and the

green -7 LED just turns off.

(041121)