ATTACK/RELEASE SELECT:

This switch selects how the compressor reacts to a
increase (attack) or decrease (release) of the input
signal.

There are two settings of the switch:

1.

Manual.
attack time: from 0.3 msec to 10 msec
release time: from 0.07 sec to 2 sec

2.

Preset.

attack

release

pos 1.

1,5 mS

0,25 S

pos 2.

1,5 mS

0,8 S

pos 3.

3 mS

2,2 S

pos 4.

6 mS

5,0 S

pos 5.

3 mS

0,5/4 S

pos 6.

1,5 mS

0,5/4/20 S

The release time in position 5 and 6 is program depen-
dent, that is:
pos 5, 6

for short peaks:

0,5 S

pos 5, 6

for long peaks:

4 S

pos 6

for continuously high levels:

20 S

LIMITER:

THRESHOLD:

The threshold is related to the output level and is
continuously variable from off to 0 dBm.

ratio:

20:1

attack:

0,6mS

release:

0,5 S

We recommend that the balance adjustment of the VCA, is carried out
every 6 month.