VAC PA35/35 User Manual

Page 12

Advertising
background image

SPECIFICATIONS

The VAC System has been developed with the critical ear as the major arbiter of quality, with both conventional
and unique measurements providing insight and guidance as necessary. The lack of emphasis on measurements
is due to the fact that engineering's arsenal of equipment and techniques do not operate on the pattern
recognition principals that control human perception of sound.

In the immortal words of Daniel von Recklinghausen, if it measures good and sounds bad it is bad. If it
measures bad and sounds good you've measured the wrong things.

For those concerned with test bench performance, the following describes typical measured performance of a
PA35/35 operated at 120 VAC, 60 Hz.

Power Output:

35 watts continuous average power at 1 kHz into 8 ohms connected to the 8 ohm tap,
both channels driven @ 2% THD.

Frequency Response:

down 0.5 dB at 5 Hz and 64 kHz, ref 0 dB = 1 watt @ 1 kHz.
down 3.0 dB at 3 Hz and 115 kHz, ref 0 dB = 1 watt @ 1 kHz.

Power Bandwidth:

down 0.5 dB at 12 Hz and 50 kHz, ref 0 dB = 35 watts @ 1 kHz.
down 3.0 dB at 8.5 Hz and 85 kHz, ref 0 dB = 35 watts @ 1 kHz.

Distortion:

< .25% THD at 1 kHz 10 watts

Noise:

< 1.5 mv at the output, S/N ratio > 84 dB

Sensitivity:

varies with feedback setting

Negative Feedback:

0, 1, 2, 3, 4, 5 dB selectable

Absolute Polarity:

Does not invert signal polarity.

Fuse:

Slo-Blow type, 4A for 100 & 120 Volt configuration, 2A for 220 & 240 V.

Power consumption:

300 watts at idle, 516 watts with both channels driven to full power.

Dimensions:

18 " width x 15 " depth x 7.5 " height

Advertising