Select Control Change Numbers
Each MIDI control change (CC) message includes a controller number which
specifies the Control Switcher switch to turn on or off. You can select from eight
different groups of CC numbers.

The default group is CC numbers 80-83, which means that 80 controls switch #1,
81 controls switch #2, 82 controls switch #3, and 83 controls switch #4.

If you are using a Ground Control Pro, each group of CC numbers corresponds
to a set of four GCX loops. This allows you to force Control Switcher to respond
as if it were the specified GCX.

Here’s how you select which CC numbers Control Switcher will respond to:

1.) Apply power while holding down button #4. LED #4 will flash until you release
the button.

2.) Press buttons 1, 2 and 3 according to this table.

CC #

LED #1

LED #2

LED #3

GCX Loops

80-83 OFF OFF

OFF

GCX#1 Loops 1-4

84-87 OFF OFF

ON

GCX#1 Loops 5-8

88-91 OFF ON

OFF

GCX#2 Loops 1-4

92-95 OFF ON

ON

GCX#2 Loops 5-8

64-67 ON OFF

OFF

GCX#3 Loops 1-4

68-71 ON OFF

ON

GCX#3 Loops 5-8

56-59 ON

ON

OFF

GCX#4 Loops 1-4

60-63 ON ON

ON

GCX#4 Loops 5-8


3.) Remove power when finished.

Factory Reset
You can restore all of the factory default settings and clear any saved presets by
the following steps:

1.) Apply power while holding down both buttons #2 and #3.

2.) LED #1 will be on. Press button #1.

3.) Press buttons #2, #3 and #4 as each LED comes on.

4.) LEDs will blink and then stay on. Remove power.