Connecting a Pump Start Relay

CAUTION: To prevent timer damage, ensure the

relay current draw does not exceed 0.30 Amps. Do
not connect the timer directly to the pump starter.
1. For pump relay wires, install a 1/2″ (13mm) conduit

adapter and conduit.

2. Connect a wire pair to the pump relay terminals and

route the cable through the conduit and into the timer

housing.

3. Connect one wire to the terminal labeled COM (10).

Connect the remaining wire to the terminal labeled

PUMP/MV (9) as shown below.

CAUTION: To prevent pump damage due to

excessive back pressure, remove all unused zone
modules. Connect a jumper wire from an unused zone
terminal to a zone terminal with a valve connected.
Note:

Refer to “Pump Control” section on page 29 for

important pump circuit control information.

 Connecting the Power Source

1. Route the power and equipment ground wires from the

power source, through the conduit and into the timer

transformer compartment.

Note: The timer terminal block accepts wire size up

to 14 AWG (2mm

2

).

2. Remove 3/8″ (9mm) insulation from the wire ends.
3. Using a small flat blade screwdriver, secure the wires

as shown to the terminal block as follows:

Line or Line 1 (L1) to L, Neutral or Line 2 (L2) to N

and Equipment Ground to

.

4. Replace the transformer compartment cover.
5. Apply power to the timer.
Note:

The display will begin flashing 12:00

am

. Press any

button to halt flashing display.



24 VAC
Pump Relay

Valve Common Wire

Jumper Wire

WARNING:

AC power wiring must be installed and connected
by qualified personnel only. All electrical compo-
nents and installation procedures must comply
with all applicable local and national electrical
codes. Some codes may require a means of dis-
connection from the AC power source installed in
the fixed wiring and having a contact separation
of at least 0.120

in the line and neutral poles.

Make sure the power source is OFF prior to con-
necting the timer.

10