DATA FORMAT

Description

String

H

EADER

P

OSITION

see par. 4.3.1

First frame field

ES0

Before message field

ES1

C

ODE

L

ENGTH

TX

Code length not transmitted

EE0

Code length transmitted in variable-digit length

EE1

Code length transmitted in fixed 4-digit format

EE2


The code length is transmitted in the message after the Headers and Code Identifier
characters.
The code length is calculated after performing any field adjustment operations.

A

DDRESS

S

TAMPING

see par. 4.3.2

Disable

RU0

Enable

RU1

A

DDRESS

D

ELIMITER

see par. 4.3.3

Disable

RV0

Enable

RV1a

a = a Hex value representing the ASCII character in the range from 00 to FE in Appendix B.