PROBLEM

POSSIBLE CAUSE

SOLUTION

Air leak near the top of the tool or in the
trigger area

Loose screws
Worn or damaged O-rings or seals

Tighten screws
Install Overhaul Kit

Air leak near the bottom of the tool

Worn or damaged O-rings or bumper

Install Overhaul Kit

Tool does nothing or operates sluggishly Inadequate air supply

Worn or damaged O-rings or bumper

Verify adequate air supply
Install Overhaul Kit

Tool jams frequently

Incorrect fasteners
Damaged fasteners
Loose magazine
Dirty magazine
Worn or damaged driver

Verify that fasteners are the correct size
Replace fasteners
Tighten screws
Clean magazine
Install Driver Maintenance Kit