TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

SOLUTION

Work-contacting element does not
depress fully - tool does not operate.

Low nails
Work-contacting element is jammed

Replenish nails
Remove battery and clear debris

Tool operates properly, but fasteners do
not drive fully

Air pressure is too low
Depth of drive isn’t deep enought
Nail is too long for wood hardness

Increase air pressure
Adjust depth of drive
Use nail length that is appropriate for
wood

Tool operates properly, but fasteners are
driven too deep

Air pressure is too high
Depth of drive is too deep

Decrease air pressure
Adjust depth of drive

Tool jams frequently

Incorrect nails
Damaged nails
Loose magazine
Dirty magazine

Verify that nails are the correct size
Replace nails
Tighten screws
Clean magazine

Tool stops and LED’s flash rapidly

Battery is low or has no charge.
Tool is hot

Recharge battery
Allow tool to cool

Tool has charged battery and LED’s
are slowly flashing or LED’s do not turn
off after approximately ten seconds of
non-use.

Tool has malfunctioned

Take tool to nearest authorized repair
center

Advertising