0432-INS-400 Rev. E

5-4

Figure 5-6 By changing the Low/High values for a
displayed parameter in the Graph Setup…

2. Make a few welds using weld settings and parts customary for the application. After each weld is

made, notice the weld number increase by one.
• Use the MENU key to go to the Main Menu. Select Data, then Halfcycle Summary. The

screen should look similar to figure 5-5.

At the top of the screen is the name of the
master to which the weld number at the
bottom of the screen was compared. If there
was no master in use when the weld was
made, it will say No Master. Below the
master name are two parameter boxes. The
parameter on the left is represented by the axis
on the left; the parameter on the right is
represented by the axis on the right. You can
select either box and scroll through the list to
change which two parameters are displayed.
The parameter in the left box will be displayed
as a non-bold line. The parameter in the right
box will show up as a bold bright solid line. If
you have trouble differentiating between the
two, select the same parameter in both boxes.
The horizontal axis is measured in halfcycles.

If the graph extends vertically off the screen, you can change the graph display range by doing the
following:

1. ESCAPE to the Main Menu. Select Setup, then Graph Setup.

2. Select the value in the Graph Low or Graph High boxes that correspond with the parameter

displayed in the Halfcycle Summary screen and scroll through or type in the desired high / low
value. When you return to the Halfcycle Summary screen, the changes will take effect
immediately.

Figure 5-5 Halfcycle Summary (graph)

Figure 5-7 …you can alter the graph display on the
monitor.