MOISTURE GUARD PLUS

®

Ice & Rain Protective Underlayment

APPLICATION INSTRUCTIONS

Roof
Deck

3-1/2" edge lap

Roof

Deck

MOISTURE GUARD PLUS
UNDERLAYMENT FIELD APPLICATION

VALLEY FLASHING
DETAIL

©

2013 TAMKO Building Products, Inc. TAMKO

®

and MOISTURE GUARD PLUS

®

are a registered trademark of TAMKO Building Products, Inc.

tamko.com

Corporate

220 West 4th Street, Joplin, Missouri 64801

800-641-4691

Central District

220 West 4th Street, Joplin, Missouri 64801

800-641-4691

Northeast District

4500 Tamko Drive, Frederick, Maryland 21703

800-368-2055

Southeast District

2300 35th Street, Tuscaloosa, Alabama 35401

800-228-2656

Southwest District

7910 South Central Expressway, Dallas, Texas 75216

800-443-1834

Western District

5300 East 43rd Avenue, Denver, Colorado 80216

800-530-8868

SURFACE PREPARATION

To begin, remove any dust, dirt, loose nails or other protrusions from the deck of new roofs. Remove all shingles, roofing felt, nails, or other

existing roofing materials and debris from the deck of existing roofs. Sweep thoroughly to remove any dust and dirt. For best application, apply

MOISTURE GUARD PLUS only in fair weather and when air, substrate, and membrane temperatures are above 35° F.

FOR ROOF DECKS

Apply MOISTURE GUARD PLUS from low to high in shingle fashion as shown below, so that laps will shed water. Overlap edge seams

3-1/2". End seams should be overlapped 6" and staggered. When necessary, the membrane may be unrolled and cut in 10- to 15-foot lengths.

Align the membrane on the lower edge of the roof deck. Remove the release film from the membrane then press the membrane into place. Roll

lower edges of each course firmly with a wallpaper roller or other hand roller; "Broom in" the installed membrane using an industrial flat broom

or squeegee. Bear down on the installed membrane with the broom or squeegee to insure total, even adherence to the substrate. Care should be

taken not to damage the surface when brooming. For ice dam protection, MOISTURE GUARD PLUS must be applied to reach a point above

the highest expected level of ice dams (minimum application at least 24" beyond the interior wall line.)

FOR VALLEYS AND RIDGES

Where necessary, the membrane may be unrolled and cut into 4- to 6-foot lengths. Peel the release film and center sheet over valley or ridge.

Drape and press sheet into place, working from the center of the valley or ridge outward in each direction. For valleys, apply the membrane

starting at the lowest point and work upward. Overlap all sheets a minimum of 6 inches. The MOISTURE GUARD PLUS underlayment should

be used on "closed valley" applications only. It must be covered by roofing materials. MOISTURE GUARD PLUS underlayment must not be

exposed to the elements longer than 90 days before application of the finished roof.

THESE ARE THE APPLICATION INSTRUCTIONS FOR MOISTURE GUARD PLUS UNDERLAYMENT. TAMKO BUILDING

PRODUCTS SHALL NOT BE RESPONSIBLE FOR LEAKS OR OTHER ROOFING PROBLEMS RESULTING FROM FAILURE TO

FOLLOW THESE INSTRUCTIONS. For questions about MOISTURE GUARD PLUS or it's application contact TAMKO's Technical

Services Department at 800-641-4691.

PROVIDE VENTILATION WHEN USING OVER THE ENTIRE ROOF DECK

When using MOISTURE GUARD PLUS underlayment over the entire roof deck the roof must include a system to provide adequate

ventilation for all space immediately below the roof deck. Such ventilation system should be designed in accordance with architectural

design standards appropriate to the size, nature, and location of the structure and should include both ridge and soffit venting. For further

information on providing adequate ventilation, contact your architect, building contractor, building materials supplier, or TAMKO.

IMPORTANT:

Tiles can slide during roof loading and until properly fastened. In order to protect MOISTURE GUARD PLUS underlayment

from damage, care must be taken to insure stability of stacked tiles. Fasteners and batten strips must be used when installing

tiles over MOISTURE GUARD PLUS underlayment. TAMKO requires the fastening of every tile in addition to mortar, or

adhesive or foam regardless of the slope. These are TAMKO's minimum requirements. State and local registrations may contain

additional requirements.

SAFETY PRECAUTION

Personal fall protection devices should always be used when applying MOISTURE GUARD PLUS. Moisture, frost or debris may

decrease the traction while walking on MOISTURE GUARD PLUS. PLEASE EXERCISE CAUTION DURING INSTALLATION.