APPLICATION INSTRUCTIONS

SAFETY PRECAUTION

Personal fall protection devices should always be used when applying TAMKO PEEL‑N‑STICK FELT. Moisture,

frost or debris may decrease the traction while walking on TAMKO PEEL‑N‑STICK FELT. PLEASE EXERCISE

CAUTION DURING INSTALLATION.
SURFACE PREPARATION

To begin, remove any dust, dirt, loose nails or other

protrusions from the deck of new roofs. Remove all shingles,

roofing felt, nails, or other existing roofing materials and debris

from the deck of existing roofs.

Sweep thoroughly to remove any dust and dirt. Apply

PEEL‑N‑STICK FELT only in fair weather and when air,

substrate, and felt temperatures are above 35º F.
FOR ROOF DECKS

Apply PEEL‑N‑STICK FELT from low to high in shingle fashion as

shown below, so that laps will shed water. Overlap edge seams

4". End seams should be overlapped 6" and staggered. When

necessary, the felt may be unrolled and cut in 10‑ to 15‑foot lengths.

Align the felt on the lower edge of the roof deck. Remove the release

film from the felt then press the felt into place. Roll lower edges

of each course firmly with a wallpaper roller or other hand roller.

“Broom in” the installed felt using an industrial flat broom or

squeegee. Bear down on the installed membrane with the broom

or squeegee to insure total, even adherence to the substrate.

Care must be taken not to damage the surface when brooming.
FOR VALLEYS AND RIDGES

Where necessary, the felt may be unrolled and cut into 4‑ to 6‑foot

lengths. Peel the release film and center sheet over valley or

ridge. Drape and press sheet into place, working from the center

of the valley or ridge outward in each direction. For valleys, apply

the felt starting at the lowest point and work upward. Overlap all

sheets a minimum of 6 inches. PEEL‑N‑STICK FELT must be

covered by roofing materials immediately.
PROVIDE VENTILATION WHEN USING

OVER THE ENTIRE ROOF DECK

When using PEEL‑N‑STICK FELT over the entire roof deck the

roof must include a system to provide adequate ventilation for all

space immediately below the roof deck. Such ventilation system

should be designed in accordance with architectural design

standards appropriate to the size, nature, and location of the structure and should

include both ridge and soffit venting. For further information on providing adequate

ventilation, contact your architect, building contractor, building materials supplier, or

TAMKO.
For questions about TAMKO PEEL‑N‑STICK FELT or its application,

contact TAMKO’s Technical Services Department at 800‑641‑4691.

4" edge lap

6" end lap

Roof

Deck

Roof

Deck

6" min.

lap

4' - 6'

lengths

Valley centerline

©2010 TAMKO Building Products, Inc. TAMKO is a registered trademark of TAMKO Building Products, Inc.

TAMKO

®

PEEL‑N‑STICK FELT

Underlayment

THESE ARE THE APPLICATION INSTRUCTIONS FOR TAMKO PEEL‑N‑STICK FELT. TAMKO BUILDING

PRODUCTS, INC. SHALL NOT BE RESPONSIBLE FOR LEAKS OR OTHER ROOFING PROBLEMS

RESULTING FROM IMPROPER APPLICATION. PLEASE BE ADVISED THAT THIS PRODUCT IS SOLD

"AS IS". TAMKO MAKES NO WARRANTIES, EXPRESSED OR IMPLIED OR STATUTORY INCLUDING,

BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MECHANTABILITY AND FITNESS FOR A

PARTICULAR PURPOSE.

Advertising