TAMKO Curb Mount User Manual

Curb mount, Application instructions for

Advertising
background image

CURB MOUNT

TAMKO SOLAR ATTIC VENT
MODELS 31001281 • 31001282

1

Central District

220 West 4th St., Joplin, MO 64801

800-641-4691

Northeast District

4500 Tamko Dr., Frederick, MD 21701

800-368-2055

Southeast District

2300 35th St., Tuscaloosa, AL 35401

800-228-2656

Southwest District

7910 S. Central Exp., Dallas, TX 75216

800-443-1834

Western District

5300 East 43rd Ave., Denver, CO 80216

800-530-8868

Visit Our Web Site at

tamko.com

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.

If you have any questions, contact TAMKO’s Technical Systems
Department at 1-800-641-4691.

2. Before servicing or cleaning unit, disable the ventilator by

covering the solar panel with cardboard taping it to the unit to
prevent motor from running. Then disconnect the wires from
the motor terminals (note wire locations before disconnecting
so wires can be re-connected in the proper location).

3. Installation work must be done by a qualified person(s) in

accordance with all applicable codes and standards, including
fire-rated construction codes and standards.

4. If removing an existing 120 VAC powered attic ventilator, use

only a qualified person(s) to remove any electrical wiring in
accordance with all applicable codes and standards.

5. When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities.

6. Stay away from all power lines

TOOLS AND MATERIALS REQUIRED

Safety Glasses and Hearing Protection

Drill

1/4" Drill Bit

Sabre Saw or Keyhole Saw

Hammer

Ruler/ Tape Measure

Pencil, Marker or Scribe

Utility Knife

Pry Bar (to remove roofing nails)

5/16" Socket and Extension

TAMKO’s TAM-PRO SBS Adhesive or

TAMKO TAM-SEAL Adhesive

Galvanized Roofing Nails (1-3/4" in.)

CAUTION

DO NOT REMOVE CARDBOARD UNTIL INSTALLATION IS

COMPLETED.
1. For general ventilating use only. Do not use to exhaust

hazardous or explosive materials or vapors.

2. To avoid motor bearing damage and noisy and/or unbalanced

impellers, keep drywall spray, construction dust, etc. off the
unit.

3. This unit has an unguarded impeller.

Do not use in locations

readily accessible to people or animals.

4. This ventilator operates when the solar panel is exposed to

sunlight. To reduce risk of injury while installing, servicing
or cleaning unit, cover the solar panel with cardboard
then disconnect the wires from the motor terminals (note
wire locations when disconnecting so the wires may be
re-connected in the proper location).

5. Your attic vent installation will create a screened opening into

your attic space. During a heavy rain storm there could be a
light spray of rain into this attic space. This is a normal condition
with all attic ventilators and will not cause any damage to the
structure.

Do not store any valuable articles directly under

the fan opening in the roof.

6. This ventilator is intended for roof installation. TAMKO Model

31001283 Gable Mount Ventilator is available for side wall
applications.

7. The plastic ventilator dome and base may be painted with high

quality paint. Follow the paint manufacturer’s recommendations
for acrylic and ABS plastic as appropriate. Take care to avoid
getting paint on the solar panel.

8. Please read specification label on product for further information

and requirements.

9. When working with asphalt shingles in cold weather (below 40°

F), take care to avoid damage to the shingle edges and corners.

Application Instructions for

(Continued)

THESE ARE THE MANUFACTURER’S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED.
TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING PROBLEMS RESULTING
FROM FAILURE TO FOLLOW THE MANUFACTURER’S INSTRUCTIONS.

This product carries a Six (6) Year Limited Material Warranty on all parts except the fan motor which carries a Two (2) Year Limited
Warranty. See Limited Warranty section of this document for details. To obtain an additional copy of TAMKO’s Limited Warranty,
visit us online at tamko.com of call us at 800-641-4691. The obligations contained in the Limited Warranty are expressed in lieu of all
other obligations, guarantees, warranties, expressed or implied, including any implied warranties of merchantability or fitness for a
particular purpose, and other obligations of liability on the part of TAMKO.

IN COLD WEATHER (BELOW 40°F), CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES.

This product has been designed to ventilate an area of up to 1,600 sq. ft.* of attic floor space. For larger areas, multiple ventilators will be
necessary. The number of ventilators required will vary depending on roof slope, attic configuration and sq. ft. of open air inlets. For the
ventilation requirements of your building, please contact an architect or building professional.

*1,600 sq. ft. based on 3/12 roof slope with open attic space. Contact an architect or a

building professional to determine the ventilation requirements of your building.