Troubleshooting – Nexen TL60-A 951243 User Manual
Page 12
12
FORM NO. L-20138-U-0912
TROUBLESHOOTING
SYMPTOM
PROBABLE CAUSE
SOLUTION
Failure to engage.
Insufficient air pressure to the Torque
Limiter.
Check the air lines for leaks and replace damaged
air lines.
Damaged or leaking O-ring Seals.
Replace the O-ring Seals.
Failure to
disengage.
Broken Compression Springs.
Replace the Compression Springs.
Air not exhausting from the Quick Exhaust
Shuttle Valve.
Replace the Quick Exhaust Shuttle Valve.
Ratcheting.
Insufficient air pressure to the Torque
Limiter.
Check the air lines for leaks and replace damaged
air lines.
Damaged or leaking O-ring Seals.
Replace the O-ring Seals.
Nuisance tripping.
Proximity Sensor not properly adjusted.
Adjust the Proximity Sensor(See ADJUSTMENTS).
FIGURE 12
Dowel
Pin
Ball Seat
(Included in
Drive Flange
Assembly)
Ball
(Included in
Drive Flange
Assembly)
Drive
Flange
Assembly
Backing
Plate
Hub
Ball
Bearings
Drive
Ring
Rotary
Seal
Ball
Bearing
Compression
Spring
O-ring
Seal
Piston
Back-Up
Ring Seal
Proximity
Sensor
Ball
Bearing
O-ring
Seal
Back-Up
Ring Seal
Mounting