Caution – Nexen TL50A/4-E 803017 User Manual

Page 7

Advertising
background image

7

FORM NO. L-21174-E-1209

NOTE

Nexen pneumatically actuated devices require clean, pressure regulated air for maximum performance and

life. All seals in Nexen pneumatically operated devices are lubricated for life, and do not require additional

lubrication.
However, some customers prefer to use an air line lubricator, which injects oil into the pressurized air, forcing

an oil mist into the air chamber. This is acceptable, but care must be taken to ensure once an air mist lubrication

system is used, it is continually used over the life of the product as the oil mist may wash free the factory

installed lubrication.
Locate the lubricator above and within ten feet of the product, and use low viscosity oil such as SAE-10.
Synthetic lubricants are not recommended.
Nexen product's bearings are shielded and pre-lubricated, and require no further lubrication.

LUBRICATOR DRIP RATE SETTINGS

1. Close and disconnect the air line from the unit.

2. Turn the Lubricator Adjustment Knob counterclockwise

three complete turns.

3. Open the air line.

LUBRICATION

CAUTION

These settings are for Nexen supplied

lubricators. If you are not using a Nexen

lubricator, calibration must follow the

manufacturer's suggested procedure.

4. Close the air line to the unit when a drop of oil forms

in the Lubricator Sight Gage.

5. Connect the air line to the unit.

6. Turn the Lubricator Adjustment Knob clockwise until

closed.

7. Turn the Lubricator Adjustment Knob counterclockwise

one-third turn.

8. Open the air line to the unit.

Nexen’s Torque Limiter bearings are shielded or sealed and prelubricated, and require no further lubrication.

The Drive Flange Assembly has been prelubricated and does not require additional lubrication at start up. The amount of
lubrication is sufficient to maintain the proper coefficient of friction at the Balls and Detents.

The Drive Flange Assembly must be disassembled if lubrication becomes necessary (See PARTS REPLACEMENT).
Spread recommended lubricants (approx. 1/8" [3.2 mm] thick by 1/8" [3.2 mm] wide) evenly over Drive Flange Balls, Ball
Track, and Drive Ring Detents (See Table 4 for recommended lubricants).

TABLE 4

RECOMMENDED LUBRICANTS

Chevron SRI

Amoco Rykon Premium Grease #2

Exxon Unirex #2

Shell Dolium Grease #2

Texaco Premium #2

CAUTION

Do not over-lubricate the Drive Flange Assembly.

Over-lubrication creates a hydraulic effect within

the Torque Limiter that will adversely affect the

break-away torque.

Advertising