American Weigh Scales (AWS) V-500 User Manual

Page 4

Advertising
background image

the [ ] key again.

5. The display will show “F” for finished.

6. Remove the weight and press [ ] to turn the scale

off. Calibration is complete!

V. TROUBLESHOOTING

The primary reasons for inaccuracy or malfunction

are low batteries, incorrect calibration, overload or

operating on an unstable surface. Please keep this in

mind and maintain and operate your scale properly.

This scale is a precise instrument and must be

handled with the utmost care and caution.

[Display] Elimination of errors

-----------------------------------------------

[Lo]

Change the batteries.

[OUT2] Recalibrate the scale as shown above.

[O_Ld] You are overloading the scale. Remove the

excessive load immediately!

[UnST] Use the scale in a more stable position