9

920-0072 Rev E

9/9/2014

Modbus User Manual

SCL Command Encoding Table

Function

SCL Opcode

Parameter 1

Parameter 2 Parameter 3

Parameter 4

Parameter 5

Alarm Reset

AX

0xBA

N/A

N/A

N/A

N/A

N/A

Start Jogging

CJ

0x96

N/A

N/A

N/A

N/A

N/A

Stop Jogging

SJ

0xD8

N/A

N/A

N/A

N/A

N/A

Encoder Function

EF

0xD6

0,1,2 or 6

N/A

N/A

N/A

N/A

Encoder Position

EP

0x98

Position

N/A

N/A

N/A

N/A

Feed to Double Sensor

FD

0x69

I/O Point 1

Condition 1

I/O Point 2

Condition 2

N/A

Follow Encoder

FE

0xCC

I/O Point

Condition

N/A

N/A

N/A

Feed to Length

FL

0x66

N/A

N/A

N/A

N/A

N/A

Feed to Sensor with Mask

Distance

FM

0x6A

I/O Point

Condition

N/A

N/A

N/A

Feed and Set Output

FO

0x68

I/O Point

Condition

N/A

N/A

N/A

Feed to Position

FP

0x67

N/A

N/A

N/A

N/A

N/A

Feed to Sensor

FS

0x6B

I/O Point

Condition

N/A

N/A

N/A

Feed to Sensor with Safety

Distance

FY

0x6C

I/O Point

Condition

N/A

N/A

N/A

Jog Disable

JD

0xA3

N/A

N/A

N/A

N/A

N/A

Jog Enable

JE

0xA2

N/A

N/A

N/A

N/A

N/A

Motor Disable

MD

0x9E

N/A

N/A

N/A

N/A

N/A

Motor Enable

ME

0x9F

N/A

N/A

N/A

N/A

N/A

Seek Home

SH

0x6E

I/O Point

Condition

N/A

N/A

N/A

Set Position

SP

0xA5

Position

N/A

N/A

N/A

N/A

Filter Input

FI

0xC0

I/O Point

Filter Time

N/A

N/A

N/A

Filter Select Inputs

FX

0xD3

N/A

N/A

N/A

N/A

N/A

Step Filter Freq

SF

0x06

Freq

N/A

N/A

N/A

N/A

Analog Deadband

AD

0xD2

0.001 V

N/A

N/A

N/A

N/A

Alarm Reset Input

AI

0x46

Function ('1'..'3')

I/O Point

N/A

N/A

N/A

Alarm Output

AO

0x47

Function ('1'..'3')

I/O Point

N/A

N/A

N/A

Analog Scaling

AS

0xD1

N/A

N/A

N/A

N/A

N/A

Define Limits

DL

0x42

1..3

N/A

N/A

N/A

N/A

Set Output

SO

0x8B

I/O Point

Condition

N/A

N/A

N/A

Wait for Input

WI

0x70

N/A

N/A

N/A

N/A

N/A

Queue Load & Execute

QX

0x78

1..12

N/A

N/A

N/A

N/A

Wait Time

WT

0x6F

0.01 sec

N/A

N/A

N/A

N/A

Stop Move, Kill Buffer

SK

0xE1

N/A

N/A

N/A

N/A

N/A

Stop Move, Kill Buffer,

Normal Decel

SKD 0xE2

N/A

N/A

N/A

N/A

N/A

N/A = Not Applicable
Notes:

32-bit values may be either big-endian or little-endian. Endianness is determined by Bit 6 of the PR
command word. It is recommended that this setting be configured with the ST Configurator

TM

software.

Consult the I/O Encoding Table for details on parameter data for commands referencing I/O.