Applied Motion STAC6-Si User Manual

Stac6, Stac6-s/q/si quick setup guide, Requirements

Advertising
background image

STAC6

STAC6-S/Q/Si Quick Setup Guide

Requirements

▪ A compatible stepper motor.
▪ A small flat blade screwdriver for tightening the connectors (included).
▪ A personal computer running Microsoft Windows 95, 98, NT, Me, 2000, XP, Vista or 7 (32- or 64-bit).
▪ For STAC6-S and STAC6-Q, ST Configurator™ software, available at: http://www.applied-motion.com/products/software
▪ For STAC6-Si, Si Programmer™ software, available at: http://www.applied-motion.com/products/software
▪ An Applied Motion programming cable (included).
▪ For more detailed information, please download and read the STAC6 Hardware

Manual, available at http://www.applied-motion.com/support/manuals.

To begin, make sure you have the following equipment:

Step 1

Wire the drive to the AC power source.

(apply power only after step 4 is completed

and the programming cable is connected)

STAC6x drives accept 94-135VAC

STAC6x-220 drives accept 94-265VAC

If using an external fuse, we recommend the

following fast-acting fuses:

STAC6x

: 6 amp

STAC6x-220

: 5 amp

920-0060 Rev A

Earth Ground
Neutral
Line (Hot)

GREEN

SHIELD

RED

BLACK

WHITE

SHLD

B-

B+

A-

A+

BLUE

ORANGE

BROWN

YELLOW

A+

A–

B+

B–

8

lead

motor

Series Connected

8 Leads Parallel Connected

A+

A–

B+

B–

8

lead

motor

White

Orange

Brown

Green

Red

Yellow

Blue

Black

Orange

Red

Brown

Yellow

Blue

Black

White

Green

SHLD

SHLD

A+

A–

B+

B–

8

lead

motor

Series Connected

8 Leads Parallel Connected

A+

A–

B+

B–

8

lead

motor

White

Orange

Brown

Green

Red

Yellow

Blue

Black

Orange

Red

Brown

Yellow

Blue

Black

White

Green

SHLD

SHLD

GREEN

SHIELD

RED

BLACK

WHITE

SHLD

B-

B+

A-

A+

BLUE

ORANGE

BROWN

YELLOW

Wire the motor. See the STAC6 Hardware Manual for

further details.

Series connection

Use with all STAC6-220 drives and the following

motors:

▪ HT23-552, HT23-553, HT23-554
▪ HT34-495, HT34-496, HT34-497

Use with STAC6 (120) drives and the following motors:

▪ HT23-548, HT23-549, HT23-550
▪ HT34-488, HT34-489, HT34-490

Parallel connection

Do not use parallel connection with STAC6-220 drives.

Use with STAC6 (120) drives and the following motors:

▪ HT23-552, HT23-553, HT23-554
▪ HT34-495, HT34-496, HT34-497

Step 2