5 programmable output – Applied Motion TXM24Q-1AG User Manual

Page 19

Advertising
background image

19

Rev. D

920-0087

TXM24 RS232/485 Hardware Manual

3.3.5 Programmable Output

The TXM24 drives feature one optically isolated digital output (OUT). This output can be set to

automatically control a motor brake, to signal a fault condition, to indicate when the motor is in

position or to provide an output frequency proportional to motor speed (tach signal). Or the output

can be turned on and off by program instructions like Set Output (SO). The output can be used to

drive LEDs, relays and the inputs of other electronic devices like PLCs and counters. The OUT+

(collector) and OUT- (emitter) terminals of the transistor are available at the connector. This allows

the output to be configured for current sourcing or sinking.
Diagrams of various connection types follow.

Do not connect the output to more than 30 volts. The current through the output terminal

must not exceed 100mA.

+

-

OUT+

OUT-

5 - 24

volt DC

Power

Supply

Connecting a Sinking Output

Load

TXM24

COM

IN

OUT+

OUT-

PLC

Connecting a Sourcing Output

5 - 24VDC

Power Supply

TXM24

+

-

+

-

5 - 24

volt DC

Power

Supply

Driving a Relay

OUT+

OUT-

relay

1N4935 suppresion diode

TXM24

Advertising
This manual is related to the following products: