Connecting Input Signals

The BLU servo drives have four types of inputs:
• high speed digital inputs for step & direction commands or encoder following, 5 volt logic
• digital inputs for other signals, 12 - 24 volt logic
• analog input for torque and speed commands

BLU-Q and BLU-S Inputs
These drives include seven digital inputs and one analog input.
CW & CCW Limit: can be used to inhibit motion in a given direction, forcing the motor and load to
travel within mechanical limits. Can be configured for active closed, active open or not used.
STEP & DIR: digital signal commanding position. Quadrature signals from encoders can also be
used.
Servo Enable: activates servo. Can be configured for active closed, active open or not used.
Alarm Reset: Activate this signal momentarily to reset a drive fault or alarm. Can be configured for
active closed, active open or not used.
Analog In: analog torque, velocity or position command signal. Can be configured for 0-10V, 0-
5V, ±10V or ±5V, with or without offset.

BLU-SE & -QE Inputs
These drives include eight additional programmable inputs on screw terminal connectors.

Connector Pin Diagrams

DB-25 Connector

Available on all drives

X COMMON

X7/CW Limit

X6/CCW Limit

X3/Servo Enable

X5

X4/Alarm Reset

Analog IN-
Analog IN+

X2/DIR-

X2/DIR+

X1/STEP/PWM+
X1/STEP/PWM-

GND

Z-

Z+

B-

B+

A-

A+

Front View

21

22

23

24

25

13
12
11
10
9
8
7
6
5
4

2

3

1

20
19
18
17
16
15
14

Shared

Common

Shared

Common

Y1/BRAKE

Y2/INPOSN

Y3/ALARM

Y COMMON

+5V OUT (200 mA MAX)

GND

Encoder

Outputs