Atlona ATP 14029 User Manual
Page 3
2
www.atlona.com
Toll free: 1-877-536-3976
Local: 1-408-962-0515
Conductor
Stranded Tinned Copper
Component A:
(1 Pair +Drain Wire+ Shield)x4 8C
AWG
24
Construction (mm)
7/0.20T
Stranded Dia.(mm)
0.60
Insulation
FOAM FEP
Nom. Thickness (mm)
0.42
Insulation Dia.( ±0.05mm)
1.45
Drain Wire
(Stranded Tinned Copper) 7/0.20T Shield extended film edge
aluminum/polyester 100% coverage with 25% overlap.
Component B : 1 Pair
2C
AWG
24
Construction (mm)
7/0.20T
Stranded Dia.(mm)
0.60
Insulation
FEP
Nom. Thickness (mm)
0.17
Insulation Dia.( ±0.05mm)
0.95
Component C :5 Core
5C
AWG
24
Construction (mm)
7/0.20T
Stranded Dia.(mm)
0.60
Insulation
FEP
Nom. Thickness (mm)
0.17
Insulation Dia.( ±0.05mm)
0.95
Component A,B and C cabled together,
Shield
Aluminum/Polyester 100% coverage with 25% overlap.
Drain Wire(Stranded Tinned Copper)
7/0.20T
Braid Shield
Tinned Copper
Construction(mm)
24/9/0.12T
Coverage(%)
>= 85%
Jacket
Plenum- PVC
Nom. Thickness(mm)
0.60
Outer Dia.(± 0.20mm)
9.0
CONSTRUCTION