Atlona AT COMP 88M User Manual

Page 7

Advertising
background image

5

RS-232

Atlona’s AT-COMP-88M can be controlled via the RS-232 serial control port to allow for interfacing to a
PC. The serial communication parameters are 9600 baud, 8 bit, No Parity and 1 stop bit - this is often
referred to as 9600 8N1.

:KHQ WKH XQLW UHFRJQL]HV D FRPSOHWH FRPPDQG LW ZLOO SHUIRUP WKH UHTXHVWHG DFWLRQ  WKHUH LV QR GHOLP-
iter character required. The unit does not send out a message when a value is changed from the front
panel or IR control. If this unit needs to be controlled via the front panel in addition to the RS232 control,
UHJXODUO\ SROO WKH XQLW VWDWXV WR HQVXUH WKH FRQWURO V\VWHP DFFXUDWHO\ UHÀHFWV WKH FXUUHQW VHWWLQJV RU VLPL-
lar third party control system.

PROTOCOL COMMANDS

To Switch Inputs to Outputs
SBI0XO0Y :KHUH ; LV

the Input 1XPEHU  DQG < LV the Output 1XPEHU 

8QLW ZLOO UHVSRQG ZLWK
SBUD0XOY- :KHUH ; LV

the Input 1XPEHU  DQG < LV the Output 1XPEHU 

([DPSOH  6HQG ,QSXW  WR 2XWSXW 
SBUD08O3-Send
SBI08O03-Rcvd

STANDBY MODE

Note: Turning the unit System Power Off over RS232 will distinguish the LED display leaving only the
Power Switch LED on. The Video and Audio outputs will also mute. While the unit is turned off by
RS232 it will continue to accept and act upon switching commands. For example, if the unit is in the off
mode (via RS232) and you send a command to switch an input to an output, that route will complete
and the video and audio will now appear on that channel only. The front panel LED for that particular
output will also show the input selected (for that single output channel only). The remaining LED’s will
remain off and video and audio outputs muted. The unit will still return status and change messages
in response to commands sent while in Power Off state. A hard reset command (SBALLRST) will return
the unit to normal operation and also unlock the front panel.

POWER OFF MODE

SBSYSMON- Place system into Standby (Soft Power Off)
SBSYSMOF- Bring unit out of Standby (Soft Power On)

8QLW ZLOO UHVSRQG ZLWK
SBALOFAK 8QLW LV LQ 6WDQGE\
SBALONAK 8QLW LV QR ORQJHU LQ 6WDQGE\

([DPSOH  3XW 8QLW LQ 6WDQGE\ 6RIW 3RZHU
SBSYSMOF - Put system into Standby (Soft Power Off)
SBSYSMON - Bring unit out of Standby (Soft Power On)

RS-232 PROTOCOL COMMANDS

Advertising