Dimensiones, Menu setup, Self-reclosing sequences configuration – CIRCUTOR WRU-10-MT User Manual

Page 2: Accessories, Load, Shunt coil undervoltage coil

Advertising
background image

MENU SETUP

mS

mA

mA

REC

mS

mA

mA

REC

mS

mA

mA

PROG

mS

mA

mA

PROG

m

S

m

A

mA

PROG

m

S

m

A

mA

PROG

mS

mA

mA

PROG

mS

mA

mA

PROG

t

d

PROG

PROG

GUARDA CAMBIOS
SAVE CHANGES

SALIR SETUP
EXIT SETUP

mS

mA

mA

PROG

PROG

mS

mA

mA

PROG

t

d

mS

mA

mA

PROG

mS

mA

mA

PROG

t

d

mS

mA

mA

PROG

mS

mA

mA

PROG

t

d

t

d

PROG

t

d

t

d

%

PROG

mS

mA

mA

PROG

mS

mA

mA

PROG

t

d

mS

m

S

mS

mA

mA

PROG

mS

mA

mA

PROG

t

d

PROG

mS

mA

mA

PROG

mS

mA

mA

PROG

t

d

PROG

PROG

PROG

PROG

PROG

t

d

mS

mA

mA

PROG

mS

mA

mA

PROG

mS

mA

mA

PROG

PROG

t

d

t

d

mS

mA

mA

PROG

t

d

PROG

PROG

PROG

DIMENSIONES

SELF-RECLOSING SEQUENCES CONFIGURATION

REC

REC

PROG

BY

EAR

TH LEAKAGE F

AUL

T

PROG

PROG

REC

REC

BY

SHORTCIRCUIT/OVERLOAD F

AUL

T

Without trip coil

With trip coil
Shunt coil, TRIP SC
Undervoltage coil, TRIP UC

INStantaneous Protection, 30 mA
only with shunt coil.

Earth leakage protection and self-reclosing
system by means of external breaking element
asociated to output contacts 9-10-11-12

.

MOTORIZED CIRCUIT
BREAKERS:

- WITH COIL
- WITHOUT COIL

ACCESSORIES

PLUG IN
CONNECTORS

mS

mA

mA

REC

SUBMENUS SP(ALAR) and AU(ALAR) are disabled when trip with coil are activated.

TRIP:

SETTING SETUP

TRIP:

Shunt coil

Undervoltage coil

SETTING SETUP

M98232601-03-14A

FREC

LIM

ALAR

RSTC

Button

PROG

50 Hz
60 Hz

10 s, 30 A

I

d

t

d

SP

Pre-alarm current %

Delay pre-alarm seg.

Contact NO/NC

AU Reconectable

1 s, 3 A

OFF
50
60
70
80
MAIN
0,02
0,1
0,2
0,3
0,4
0,75
1
3
NO
YES
AUTO
MANU
NO
YES
Cb
SC
UC

Button

TRIP

- FREQ,

(50) frecuency (Hz)

- LIM,(1s, 3A), range of values (Id / td)
- ALAR, pre-alarm.
. Id ( OFF), It’is not pre-alarm.
. Td ( 20 ms), time.
. SP (NO),contact states.
3-4 [NA/NC]
.AU (AutO), Relay reclaim the state.
- RSTC, (NO), Reset the partial reclosures.
- TRIP, (Cb), Motorized circuit breaker.

Default values in SETUP

WRU-10 MT Electronic Earth-leakage Protection Relay

CONNECTION WRU-10MT + MT- 62/64

MENU SETUP

N

L1 L2 L3

M

N

L

O

I

12

11

Reset

Test

WRU-10 MT

4 5 6

3

9 10 11

7

8

1

2

12

LOAD

R

Id

MT

- C- 62/64

External
ON/OFF

Alarms

Protection relay
with self-reclosing

230 Vac

MENU SETUP

N

L1 L2 L3

M

N

L

O

I

12

11

Reset

Test

WRU-10 MT

4 5 6

3

9 10 11

7

8

1

2

12

LOAD

R

MT

- C- 62/64 + F6

External
ON/OFF

Alarm

Protection relay
with self-reclosing
SETUP: TRIP Sh

U>

C1

C2

230 Vac