CUE keyboardCUE-S User Manual

Page 8

Advertising
background image

4.2. Addressing of keyboardCUE-S (serial number

CS0174.0129 and above)

The ADDRESS of the keyboardCUE-S can be set in the range 0 to 255. Default keyboard ADDRESS
is 0.

The BUTTON_ID transmitted by a panel and BUTTON_LED_ID (tabletop model keyboardCUE-S only)
are numbers used in the programming for button and bargraph identification. Both values depend on
a button position and it depends on a keyboard ADDRESS too. Both values are calculated according
formulas

BUTTON_ ID

= Offset + Button Code


BUTTON_LED_ID

= Offset + Button Code


Offset

= 32 * ADDRESS


The lowest BUTTON_ID is generated by a button in the upper left corner the highest BUTTON_ID is
generated by a button in the lower right corner - see example for ADDRESS = 0 on the picture below.


In the table below there is Button ID range for some addresses.

ADDRESS

BUTTON_ID range = BUTTON_LED_ID range

0 1 8

1 33 40

2 65 72

… … …

9 289 296

User Manual Small Keyboards

www.cuesystem.com

Page 8 of 18