DekTec DTE-3114 IP to 4x QAM User Manual

Page 43

Advertising
background image

DTE-3114 – Networked Quad QAM Modulator

USER MANUAL

43

::= { nwTxEntry 3 }

nwTxChannelEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable this channel.
0 disable the channel
1 enable the channel"
DEFVAL { disable }
::= { nwTxEntry 4 }

nwTxIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination IP address. The generated IP stream will be sent to this IP address."
::= { nwTxEntry 5 }

nwTxIpPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination IP port. The generated IP stream will be sent to this IP port."
::= { nwTxEntry 6 }

nwTxTimeToLive OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time to live. The generated IP packets will use the
TTL specified by this value."
::= { nwTxEntry 7 }

nwTxProtocol OBJECT-TYPE
SYNTAX INTEGER {
udp(0),
rtp(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP protocol used for generated IP packets.
0 generate UDP packets
1 generate RTP packets"
::= { nwTxEntry 8 }

nwTxNumberOfTpPerIp OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of transport packets per IP packet. A value of 0
means that this MIB object is irrelevant, e.g. for SDI-over-IP"
::= { nwTxEntry 9 }

nwTxFecEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable FEC generation.
0 do not generate a FEC stream
1 generate a FEC stream (only if 'nwTxProtocol' is set to RTP)"
::= { nwTxEntry 10 }

nwTxFecNumberOfRows OBJECT-TYPE
SYNTAX Integer32 (0..20)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of FEC rows to generate."
::= { nwTxEntry 11 }

Advertising
This manual is related to the following products: