Ph2 - projector hinge – Future Automation PH User Manual

Page 15

Advertising
background image

Page 14 of 20 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565

PH2 - Projector Hinge

In

st

all

at

io

n

: E

le

ctr

ic

al

C

on

ne

cti

on

Contact Closure

Use an RJ45 connector in the
CCI socket on the control box
to operate via contact closure





SLQV

LED 1
LED 2
LED 3

LED 4
LED 5

CONTACT CLOSURE INPUT

NOTE:
Earlier versions of the control board
may not have these contact closure
LED indicators.

568A

568B

1

12V SUPPLY

12V SUPPLY - CURRENT LIMITED

W/G

W/O

2

12V LATCH

When 12V attached, device will go OUT. When

12V removed, device will go IN.

G

O

3

GROUND

GROUND

W/O

W/G

4

DEVICE LATCH

Short to GROUND (pin 3), device will go OUT,

remove short device will go IN.

BL

BL

N / A

5

PIN 4 NOT USED

W/BL

W/BL

N / A

6

DEVICE STOP

Momentary short to GROUND (pin 3), stops

device in current position.

O

G

N / A

7

DEVICE OUT

Momentary short to GROUND (pin 3), makes

device go OUT.

W/BR

W/BR

N / A

8

DEVICE IN

Momentary short to GROUND (pin 3), makes

device go IN.

BR

BR

N / A

PIN

DESCRIPTION

ACTION

WIRE / CABLE

CONTACT CLOSURE

LED INDICATOR