Operation and controls, Front panel control, Back panel control – Holland Electronics HSA User Manual

Page 3

Advertising
background image

1

Rev. 06/03

Operation and Controls

1.

Channel Identifier:

Indicates the channel for which the unit has been preset.

2.

Power Indicator:

Indicates power is on when lit.

3.

Output Test:

A -30 dB output test port is provided for ease of system alignment.

4.

RF Gain, AGC:

The RF output level and the AGC threshold are controlled from this

potentiometer.

5.

Aural Level:

This tunable notch filter allows adjustment of the audio

carrier level.

6.

Input Test:

A -20 dB input test point is provided to monitor the incoming signal level.

Front Panel Control

PAL -*

120VAC

60Hz 10W

RF IN

600 VA MAX

+

+

+

+

+

+

+

OUT

1.

IN:

The signal originating from a broadband or yagi antenna is connect-

ed at this F connector.

2.

OUT:

The filter amplified signal is directly available at this F connector.

3.

Convenience Outlet:

This outlet is provided to allow the chaining of amplifiers in the head-

end equipment rack.The polarized AC outlet is capable of delivering up

to 250 watts of AC power.

4.

Power Cord:

This three prong polarized power cord is approved by both UL and

CSA for safe operation of the amplifier. Do not cut the ground termi-

nal for both safety and operational reasons. Connect to 108 to 125

VAC, 50/60 Hz electrical outlet.

Back Panel Control

1

2

3

4

1

2

3

4

5

6

Advertising