Installation

Ilumiline Inground IP Optic 25 Series User Manual Rev. 10

9


Ilumiline
Inground IP
products must be

linked using DMX cable in
a daisy chain (serial)
fashion. To comply with
the EIA-485 standard, no
more than 32 products
should be connected on
one daisy chain without
using a DMX optically-
isolated splitter. Doing
otherwise may result in
deterioration of the digital
DMX signal.

DMX Linking

You may link both Ilumiline Inground IP products to a DMX controller using a standard DMX
serial connection. If using other DMX products compatible with the Ilumiline Inground IP
product, you can control each individually with a single DMX controller.

If you are not familiar with the DMX standard, or if you need information about the DMX cables
needed to link the Ilumiline Inground IP products to a DMX controller, you may download the
“DMX Primer” document from the ILUMINARC® website at

www.iluminarc.com

.

DMX Modes

The Ilumiline Inground Tri-12 IP Optic 25 RGB has five (5) different personalities. The
Ilumiline Inground 12 IP Optic 25 WW has only one (1).

Both products use a standard DMX data connection.

Refer to the

Introduction

chapter for a brief description of these modes. To configure

either one of the Ilumiline Inground IP products to work in these modes, refer to
the

Operation

chapter. In addition, the

DMX Values

section provides detailed

information on these DMX modes.

Refer to the tables below for the highest DMX starting address recommended for each
mode.

Ilumiline Inground Tri-12 IP Optic 25 RGB

DMX Mode

DMX Address

DMX Mode

DMX Address

ARC FULL

506

SOLID

512

ARC1

510

SPECIAL1

507

ARC1+D

509

Ilumiline Inground 12 IP Optic 25 WW

DMX Mode

DMX Address

SOLID

512

Advertising