D*ap8 – Junger Audio D*AP8 Digital Audio Processor User Manual

Page 17

Advertising
background image

D*AP8

15

Setup GUI – SYSTEM – System Status


The system status is a special link you can reach independently from where you are :


The System Status page provides a top level view of the various status information available for the device.

Device Status

provides the hardware status of the D*AP8 unit.

Power 1

status of the first power supply (left hand side from rear).

Power 2

status of second power supply (right hand side from rear).

Temperature

measured on the surface of the main PCB.

Sync Lock

turns red if the external sync source is removed or unstable.


Processing Status

Bypass

turns red if Bypass is activated.


Interface Status

AES I/O

turns red if an AES input that is internally in use (i.e. you have routed it to
an input of a function block) has detected an error.

Interface 1 SDI I/O

turns red if the SDI input is not locked (not present or bad SDI signal).


Dolby Processing Status

Decoder

turns orange if the input signal is not Dolby encoded (PCM).

Encoder A

status of the first D-E encoder (if license is installed).

Encoder B1

status of the first D-D/D-D+/AAC encoder (if optional CAT561 is installed).

status of the D-E encoder (if optional CAT569 is installed).

Encoder B2

status of the second D-D/D-D+/AAC encoder (if optional CAT561 is
installed).

Metadata

status of the metadata.

Advertising
This manual is related to the following products: