KBC Networks H.264 Encoder User Manual

Page 7

Advertising
background image

Encoder User Manual

Manual-H264_ENC-Rev1207A
Copyright © KBC Networks 2012

Page 7 of 49

www.kbcnetworks.com

2.2.2 Left Side View














Item

Connection Detail

8a

Connect to camera before powering
encoder

9b

RX- Connect to Camera RX- in 4-wire set up

9c

RX+ Connect to Camera RX+ in 4-wire set
up

9d

TX- Connect to Camera RX- in 2-wire set up

9e

TX+ Connect to Camera RX+ in 2-wire set
up

10f

Switches 1~4 OFF shown in diagram

10g

Switches 5~8 ON shown in diagram

2.2.3 RS Protocol Dip Switch Selection

2.2.3.1 RS-422 / 485

The default configuration is set for RS-422 / 485. In the diagram below, white
represents the switch. The first four dip switches OFF (in the up position) with the
last four ON will set the encoder for RS-422 or 485 protocol.




Note:

The dip switches will not determine the Baud Rate. The Baud Rate must be

configured within the GUI to match the decoder, camera and PTZ system. The
default configuration is 9600 BPS.

2.2.3.2 RS-232

The reverse dip switch positions (i.e. first four ON/down and second four OFF/up)
will change the encoder into RS-232 mode.






8. Video In BNC

9. RS Data Input
10. RS Data Selector Switch

Default Configuration: RS-485/422 (shown)

8

9

10

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

O
N

O
N

a

b c d e

f

g

Advertising