Ethernet Switch User Manual

Manual-ESUG8P_Series_HW-Rev1112
Copyright © KBC Networks Ltd.

Page 8 of 14

www.kbcnetworks.com

2.5 Power Connections

A 6 pin, power terminal block should be used to connect the power cable to the unit.


Figure 2.1 Power connections

Contact number

Connections

1

PWR2: -

2

PWR2: +

3

Fault alarm contact

4

Fault alarm contact

5

PWR1: -

6

PWR1: +

Note:

If only using one power source, connect pin 1 to pin 5 and pin 2 to pin 6

otherwise the Power Fault Alarm will be lit.

2.6 Fault Alarm Contact

The fault alarm contacts are in the middle of the 6 pin, screw block terminal on pins 3 &
4. An open circuit will occur if a power failure is detected.

















Fig 2.2 Fault Alarm Contacts

Load

External

power

24Vdc, 1A resistance

P-Fail