5 power connections, 6 fault alarm contact – KBC Networks ESUG8P User Manual
Page 8
Ethernet Switch User Manual
Manual-ESUG8P_Series_HW-Rev1112
Copyright © KBC Networks Ltd.
Page 8 of 14
www.kbcnetworks.com
2.5 Power Connections
A 6 pin, power terminal block should be used to connect the power cable to the unit.
Figure 2.1 Power connections
Contact number
Connections
1
PWR2: -
2
PWR2: +
3
Fault alarm contact
4
Fault alarm contact
5
PWR1: -
6
PWR1: +
Note:
If only using one power source, connect pin 1 to pin 5 and pin 2 to pin 6
otherwise the Power Fault Alarm will be lit.
2.6 Fault Alarm Contact
The fault alarm contacts are in the middle of the 6 pin, screw block terminal on pins 3 &
4. An open circuit will occur if a power failure is detected.
Fig 2.2 Fault Alarm Contacts
Load
External
power
24Vdc, 1A resistance
P-Fail