Knox Video RSIII User Manual

Page 20

Advertising
background image

4 004 004 8 000 000 12 000 000 16 000 000
DONE


The DRxy command will display a limited range of outputs starting at x and ending at y.

DR35 [ENTER]
003 V003 A003
004 V004 A004
005 V005 A005
DONE

3.4.2.2 CLEARING ALL CONNECTIONS

All crosspoints can be reset to their default (off) condition by using the clear command of the
form:

C

[ENTER]

Clear all crosspoint connections

3.4.2.3 USING PATTERNS

The RSIII has memory for 16 stored routing patterns. Fifteen patterns for typical use and one for
power on restore. The power-up pattern is the pattern that is loaded when the RSIII is power
cycled or first turned on. These stored configurations are non-volatile and are thus maintained
during power interruptions. To STORE the current crosspoint pattern to one of the sixteen pattern
storage areas, send a command in the form:

Sxx [ENTER]

Where xx is 01-16.

To store the current crosspoint pattern to the power-up pattern type the command

S [ENTER]
S01 [ENTER]


To recall and load one of the sixteen stored crosspoint patterns send a command in the form:

Rxx [ENTER]

Where xx is 01-16.

To recall the power-up pattern, send the command

R [ENTER]
R01 [ENTER]


The contents of the all stored patterns can be viewed by sending the

M

command.

M [ENTER]


3.4.2.4 IMMEDIATELY CORRECTING INADVERTENT COMMANDS
If a connection was incorrectly made the operator can reverse the previous command by the

UNDO

command.

UNDO [ENTER]


3.4.2.5 OBTAINING INFORMATION ABOUT THE SWITCH
Issuing the

I

command the operator can obtain information about the switch

I [ENTER]
Copyright 2008, Knox Video Technologies
RSIII, RGBHV, 12,8,BNC, UBAS, VT, 12,8,DCAT, IP
Version 1.0.7 No Video Sync Present ID: 35447070
Serial #: CO-000000-00-000