Installation – Monroe Electronics R180av70 User Manual

Page 4

Advertising
background image

Installation

Use with reference to the R180/av70 back panel graphic and installation diagram on
the next two pages. *All subsequent references to the R180/av Series Audio/Video
Comb Filter Generator will use the R180av/70 model number.

Connect the R180/av70 Series Audio/Video Comb Filter Generator terminal
block on the rear panel to the to the SAM-MIP 921e block using two 2
conductor cables with stripped ends as follows:


R180/av70 GROUND to MIP-921e AUDIO OUT & KEY

R180/av70 KEY to CEMS 0500 NO & COM

R180/av70 AUDIO to MIP-921e AUDIO OUT

Connect COMM 2 of the MIP-921e to the CEMS 0500 EAS DATA port using
the CX506S cable supplied with the CEMS 0500.

Connect VIDEO OUT of the CEMS 0500 to VIDEO IN of the R180/av70 (To
acquire the best possible picture adjust the video level on the back of the
R180/av70 with the VIDEO LEVEL control.

Loop the headend output through the R180/av70 using the RF IN and OUT
ports.

Adjust the output level of the R180/av70 to match the output of the headend
using the OUTPUT LEVEL control on the rear of the R180/av70. The output
level is factory preset to +33 dB. To activate the unit during testing, place a
jumper between KEY and GROUND in the R180/av70 terminal block on the
rear of the unit.




















Advertising