2) installation, 3) ground connections – Neotech Communications HDM-V1F1 User Manual

Page 2

Advertising
background image

HDM-V1F1 Series Quick Installation Guide

www.neotechcomm.com.tw

2

(2) Installation

2.1 General

All Neotech products are thoroughly inspected, tested and securely packaged before

delivery to ensure a stable, intact and trouble-free service. Please check the equipment upon
receipt for any visible damage which may have been caused during shipping.

The HD-SDI fiber optic converter units can be either horizontally or vertically wall-mounted,

or mounted on any fixture, etc. The Micro unit works with an external power supply 12VDC
powered by local 110/220V power.

2.2 Micro unit installation

a)

Mount the clip onto a fixture, e.g. a plank, (either on the wall or on a flat surface) with two

screws piercing through the holes on the mounting frame to secure it in position.
b) The power supply should also be mounted on the same fixture or in the proximity for
connection of the supply cables to the unit, provided that an AC power supply socket is near by
for powering the adaptor.
c)

Push the Micro unit into the clip to secure it in position.

d)

Connect all the signal inputs and outputs of the unit with appropriate cables:
i)

fiber optic cable for optical link,

ii)

BNC cable for SD-SDI or HD-SDI input/output (Tx/Rx).

e)

Once the unit is powered up, check that the red PWR LED on the unit is lit. If not, check the

power supply cable connections between the unit and the power supply socket.
f)

With all the signals available at the input and output ports, check the status of LEDs located

on the unit. With correct status of each LED, installation is now completed [for LEDs status, see
Operational Guides on this manual’s section (4)].


(3) Ground connections

For enhanced safety to reduce the risks of electrical shock and physical damage, caused by

lightning and other power surges, as well as a connection to the surge suppresion devices in the
product, a screw terminal is provided on the Micro cabinets. It is highly recommended that the
Micro unit have good ground connections to the buildings ground in accordance with the local
codes.

Advertising