C: p, Ppendix, Ower – NEXCOM NISE 104 User Manual

Page 78: Onsumption

Advertising
background image

Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.

64

NISE 104 User Manual

Appendix C: Power Consumption

a

PPendIx

C: P

oWer

C

onsumPtIon

1.Test Configuration

2.Power Consumption Measurement

3.Test Data

System Configuration

Description

Chassis

CHASSIS NISE104 VER:A

CPU

Intel® Atom™ Processor D2550

(1M Cache, 1.86 GHz)

Memory

Apacer 2GB DDR3 1066MHz SODIMM

(78.A2GC9.AF0)

CPU board

N/A

Motherboard

NISB104 REV:B

HDD

SATA2 HDD 2.5 250GB 7200RPM

HTE725025A9A364

FDD

N/A

CD-ROM

N/A

CFast

Transcend CFast 4GB (TS4GCFX5001)

Power Supply

POWER ADAPTER FSP060-DBAB1

Add-on Card

N/A

CPU Cooler

NISE104 CPU HEATSINK SHYUNG SHUHN

System FAN

N/A

Keyboard

Microsoft Wired Keyboard 600

Mouse

Microsoft Basic Optical Mouse

Purpose
The purpose of the power consumption test is to verify the power
dissipation of system, and the loading of power supply.

Test Equipment

PROVA CM-07 AC/DC CLAMP METER

Device Under Test

DUT: sys#1/

Test Procedure
1.Power up the DUT, boot into Windows 7 x32 Ultimate.
2.Entering standby mode (HDD power down).
3.Measure the power consumption and record it.
4.Run Burn-in test program to apply 100% full loading.
5.Measure the power consumption and record it.

Sys #1

Sys #1

+12V

+24V

Full-Loading Mode

1.81A

0.96A

Total

21.72W

23.04W

Standby S1Mode

0.84A

0.45A

Total

10.08W

10.8W