Appendix A: Watchdog Timer

A

ppendix

A: W

Atchdog

t

imer

Start

See “SetupWDT” procedure
#Setup Watchdog Timer Environment

Step 1

Step 2

See “TimeBaseWDT” procedure
#Initial Watchdog Timer
Users can select second or minute

Step 3

See “TimeCountWDT” procedure
#Set Watchdog Timer Time-out Value
Users can set time-out value

Step 4

See ExitSetup procedure
#Exit Setup Environment

End

WDT Programming Guide

NEX 880/890 Watchdog Function Configuration Sequence Description:

c:\>debug [enter]
-o 2e 87 ;Enter the Extended Function Mode
-o 2e 01
-o 2e 55
-o 2e 55
-o 2e 07 ;Logical Device Number Reg
-o 2f 07 ;LDN=7
-o 2e 72 ;Watch dog configuration
-o 2f XX ;minute mode or second mode
-o 2e 73 ;LSB for Watch dog tme out value
-o 2f YY
-o 2e 74 ;MSB for Watch dog tme out value
-o 2f ZZ

XX: 90 : Second mode
10 : minute mode
ex:
10 second timeout:
xx=90
yy=0a
zz=00