Power Management

▪ Selectable boot-up & shut-down voltage for low power protection by

software

▪ Setting 8-level on/off delay time by software

▪ Status of ignition and low voltage status can be detected by software

▪ Support S3/ S4 suspend mode

Dimensions

▪ VTC 7100-C8SK: 260mm (W) x 176mm (D) x 90.1mm (H)
(10.24”x 6.93”x 3.51”) 4 Kg (8 Lb)

▪ VTC 7110-C4SK: 260mm (W) x 176mm (D) x 90.1mm (H)
(10.24”x 6.93”x 3.51”) 4 Kg (8.81 Lb)

▪ VTC 7120-C4SK: 60mm (W) x 176mm (D) x 90.1mm (H)
(10.24”x 6.93”x 3.51”) 4 Kg (8.81 Lb)

Construction

▪ Aluminum enclosure with fanless design

Environment

▪ Operating temperatures:
Ambient with air: -30°C to 50°C (VTC 7110 / 7120 series)
Ambient with air: -30°C to 55°C (VTC 7100 series)

▪ Storage temperatures: -35°C to 85°C

▪ Relative humidity: 10% to 90% (non-condensing)

▪ Vibration (random): 1g@5~500 Hz (in operation, SSD)

▪ Vibration (SSD):
Operating: MIL-STD-810G, Method 514.6, Category 4, common
carrier US highway truck vibration exposure
Storage: MIL-STD-810G, Method 514.6, Category 24, minimum integrity test

▪ Shock (SSD):
Operating: MIL-STD-810G, Method 516.6, Procedure I, functional shock=20g
Non-Operating: MIL-STD-810G, Method 516.6, Procedure V, crash hazard

shock test=75g

Certifications

▪ CE approval

▪ FCC Class A

▪ e13 Mark

Power Management

▪ Power-on delay time is selectable by BIOS to disable and enable in 10sec /

30sec / 1min / 5min / 10 min / 15min / 30min / 1hr.

▪ Power-off delay time is selectable by BIOS to disable and enable in 20sec /

1min / 5min / 10min / 30min / 1hr / 6hr / 18hr.

▪ S3, S4 suspend mode

▪ Ignition On/Off status detectable by SW

▪ Low battery status detectable by SW

▪ Ignition enable/disable is jumper selectable

▪ Shut down system automatically when the system’s internal temperature

is over 80C.

▪ VTC 71 series will automatically shut down 5 minutes after the duration

of low battery voltage is over 60 sec. User can detect this situation via

software.

▪ If the ignition is off and the system is still on after 3 minutes, VTC 71

series will shut down automatically.

▪ If the ignition is off, the user can detect this status via the software.

▪ If the ignition is turned on again and the power-off delay is in progress,

VTC 71 series will cancel the delay function and will continue to operate

normally.

▪ If the ignition is turned on again and the power-off delay ended,

VTC 71 series will shut down completely will power-on again

automatically.

▪ If the ignition is turned off again and power-on delay is in progress,

VTC 71 series will cancel the delay and stay in power-off status.

▪ If the ignition is turned off again and the power-on delay ended (entered

OS already), VTC 71 series will continue to operate normally.

▪ If the ignition is turned off again and the power-on delay ended (in BIOS

process), VTC 71 series will shut down immediately.

▪ If VTC 71 series is off, only below 10mA is used.