28

DESCRIPTION

Voltage less than about 0.8V put in Micom Terminal of Number 18 and then Micom reset. Reset IC detect
Power ON and Voltage less than 4.25V, and then send Reset Signal.

Reset(8)

MICOM

18

+

CE5
4.7

µ

F

50V

IC6
7042P

R4
5.6K

5V

4.25V

H

L

t

t

POWER

ON

Vcc (+5V)

DELAY TIME

FOR POWER ON

RESET