Chapter 7, Charging the rechargeable battery cartridge – Denso CU-7011 User Manual

Page 18

Advertising
background image

8

Chapter 7 Charging the Rechargeable

Battery Cartridge

You may charge the battery cartridge loaded in the BHT.

Service Life of Rechargeable Battery Cartridge:

Lithium-ion batteries used in the battery cartridge will gradually deteriorate during
the repeated cycles of charging and discharging due to its properties, even under
normal use. When the battery run time becomes shortened due to its deterioration
even if it has been charged for the specified hours, replace the battery cartridge with
a new one. Generally, it is necessary to replace the battery cartridge after it has
undergone approx. 300 cycles of charging and discharging operation.

(1)

Plug the AC adapter of the CU-7011 into a wall socket.

The POWER LED on the CU-7011 comes on.

(2)

Place the BHT loaded with a battery cartridge onto the CU-7011.

Take care not to put the hand strap or get any foreign material between the CU
and BHT. The CU may fail to charge the battery cartridge loaded in the BHT.

The BHT turns on the indicator LED in red and starts charging. The charging time
is approx. 6 hours.

Upon completion of charging, the indicator LED turns green.

(3)

Take the BHT off the CU-7011.

BHT

CU-7011