Transportation, Troubleshooting, Specifications – Toyotomi TAD-30K User Manual

Page 6: Venting kit accessories

Advertising
background image

7. TRANSPORTATION

Preferably keep the unit in the vertical position during trans-
portation. If this is not possible then lay it on its rear side, when
at destination put the unit back in the vertical position and wait
at least ten (10) minutes before using it. Before
transporting/moving the unit make sure the drain tank is empty.

8. TROUBLESHOOTING

BEFORE CALLING FOR SERVICE
The followings are not defects.

9. SPECIFICATIONS

NOTE: Cooling air capacity will vary according to temperature

and humidity of the room.

10.VENTING KIT ACCESSORIES

If the unit is to be used exclusively in one space, the cooling ef-
ficiency will be enhanced by using the following venting kit ac-
cessories.

EXHAUST DUCT SET (FLEXIBLE TUBE) (Fig. I)

Max. 4 ft. (1.2m)

WINDOW PANEL KIT (Fig. J)

For sliding and double-hung
windows
Max. 37 in. (94cm)
Min. 28-1/4 in. (72cm)

USING EXHAUST DUCT SET (Fig. I)
1.

Insert both ends of exhaust duct hose (flexible tube) (I2) in-
to exhaust duct hose adapter nozzle (I1) by turning it
counter clockwise onto the tube and fix one of the exhaust
dust hose adapter nozzle (I1) into exhaust outlet (B3) by
turning it clockwise until it locks.

2.

Extend the exhaust duct hose (I2) and close the window or
door as far as possible trapping the exhaust duct hose
adapter nozzle (I1).

NOTE:

Place the unit as close as possible to the window
or door.

USING WINDOW PANEL KIT (Fig. J)

NOTE:

Window installations are possible by the use of
the exhaust duct set and window planel kit.

1.

Fix the exhaust duct hose grill (J3) to the window panel
with four (4) screws. Make sure that the panel is extended
so that screws do not go into sliding portion of panel.

2.

Open the window.

3.

Place the window panel in the window, extending it to fit
the width of the window. Once panel is extended, the pan-
el can be locked into this width by tightening the two (2)
screws on the top panel.

4.

Close the window.

5.

Attach the exhaust duct hose adapter nozzle (I1) on the ex-
haust duct hose grille (J3).

6.

When not in use, the exhaust duct hose adapter nozzle (I1)
may be closed off with the cover for exhaust duct hose
grille (J3) provided.

NOTE:

The same procedure can be adapted for vertical
installation in sliding windows.

3

ENGLISH

MODEL

TAD-30K

COOLING CAPACITY

10,000 BTU/H

DEHUMIDIFYING CAPACITY

0.42 gal/h (1.6 L/H)

POWER SOURCE

Single Phase 115V, 60Hz

POWER CONSUMPTION

1200 W

OPERATING CURRENT

9.5 A

AIR FLOW (MAX.)

177 CFM (300 m

3

/h)

OPERATING TEMP. RANGE

64˚F~95˚F (18˚C~35˚C)

DIMENSIONS (WxHxD)

17-1/8" x 30-1/4" x 17"

(435 x 770 x 430 mm)

WEIGHT

66 Lbs. (30 kg)

COMPRESSOR

ROTARY

REFRIGERANT

R-410A

SYMPTOM

Unit does
not work.

Unit sud-
denly stops
during in
operation.

Unit runs in-
termittently.

Unit func-
tions but the
room is not
cooled.

Condensed
water is
spilled out
when mov-
ing the unit.

CAUSE

- Power cut.

- The plug has been

plugged improperly.

- The full-tank indicator

is ON. Tank is full.

- The indoor tempera-

ture has reached the
set temperature level.

- The preset time is up.
- The full-tank indicator

is ON. Tank is full.

- Malfunction.
- Surrounding temper-

ature is too high or
too low.

- Exhaust duct hose is

blocked.

- Window or door is

left open in the room.

- There is heat source

in the room or too
many of people in it.

- Air intake grille is

clogged.

- Filter is too dirty.
- Temperature setting

is too high.

- The tank is nearly full.

SOLUTION

- Wait for power to be

supplied again.

- Plug in again.

- Remove the drain

water from the drain
tank.

- Reset the tempera-

ture level.

- Reset the timer.
- Remove the drain

water from the drain
tank.

- Contact your dealer.

- Check the duct hose.

- Close all windows

and door.

- Move out any heat

source in the room.

- Clean the air intake

grille.

- Replace the filter.
- Lower the tempera-

ture setting.

- Remove the drain

plug on the rear bot-
tom of the unit, drain
off the water then the
unit will be in opera-
tion automatically.

A hissing noise or hollow
sound :

A squeaking noise :

Odor :

The unit does not start nor
change operation mode
immediately :

e

This sound is generated from
the refrigerant flowing within
pipes.

e

This noise is generated from the
unit when it is expands or con-
tracts with temperature changes.

e

Such odor as tobacco, cosmetics,
or foods may accumulate in the
unit.

e

To prevent overloading the com-
pressor motor, the unit will be
stopped for more than 3 minutes.

TAD-30K (GB/ES/FR) 10.3.8 2:44 PM ページ 3