TROUBLESHOOTING GUIDE

22

STOVE WILL NOT FEED PELLETS, BUT FUEL FEED LIGHT COMES ON AS DESIGNED
Possible Causes:

Possible Remedies:

1. Fuse on control board blew.

Remove the control board. On the back, there is one fuse. If

it appears to be bad, replace it with a 5 Amp 125 Volt fuse.

Plug the stove back in and try to run the unit.

2. High limit switch has tripped or is defective.

Wait for the stove to cool for about 30-45 minutes. It should

now function normally. If not, use the owner’s manual to

locate the high limit thermodisc. To test if the thermodisc is

bad, you can bypass it as described previously for the POF

thermodisc.

3. Bad auger motor.

Remove the auger motor from the auger shaft and try to run

the unit. If the motor will turn, the shaft is jammed on some-

thing. If the motor will not turn, the motor is bad.

4. Auger jam

Start by emptying the hopper. Then remove the auger motor

by removing the auger pin. Remove the auger shaft inspec-

tion plate in the hopper so that you see the auger shaft.

Gently lift the auger shaft straight up so that the end of the

auger shaft comes up out of the bottom auger bushing.

Next, remove the two nuts that hold the top auger biscuit in.

Then rotate the bottom end of the auger shaft up towards

you until you can lift the shaft out of the stove. After you

have removed the shaft, inspect it for bent flights, burrs,

or broken welds. Remove any foreign material that might

have caused the jam. Also, check the auger tube for signs

of damage such as burrs, rough spots, or grooves cut into

the metal that could have caused a jam.

4. Loose wire or connector

Check all wires and connectors that connect to the auger

motor, high limit switch, and the Molex connector.

5. Bad control board

If the fuse is good, the wires and connectors check out

good, and the high limit switch did not trip, test fir power

going to the auger motor. If there is not a full current going

to the auger motor when the fuel feed light is on, you have

a bad control board.