1.1

27”, 30”, 36” wide, single,

Classic wall ovens

ECs, mCs, & PCs

CUToUT DImENsIoNs

Models

“A” Cutout Height

“B” Cutout Width

“C” Min. Cabinet Width

Oven Overlays

27”

27 3/8” (695mm)

25 1/2” (648mm)

27” (686mm)

3/4” (19mm) Each Side; 15/16” (24mm) Top;

1/16” (1mm) Bottom

30”

28 1/2” (724mm)

30” (762mm)

36”

27 3/4” (705mm)

34 1/2” (876mm)

36” (914mm)

“C”

“A”

“B”

1“ (25mm) Min.

Clear to Top of

Door for Heat

Exhaust

Alternate

Electrical

Location

Recommended

Electrical

Location

Alternate

Electrical

Location

1“ (25mm) Min.

2

3

3

1

36”

(914mm)

typ.

2 1/2”

(64mm)

to finished

Countertop

“A”

“B”

1“ (25mm) Min.

to Combustible Floor

4“ Typical Toe Kick

Alternate

Electrical

Location

Recommended

Electrical

Location

1 1/2”

(38mm)

Typical Counter

3

3

2

1

CUToUT DImENsIoNs

INsTALLED UNDEr-CoUNTEr

NOTES:

1. 24” (610mm) minimum interior cabinet depth.

Back of cabinet may need to be removed.

2. 3/4” (19mm) support platform (flush with cutout).

3. 1/8” (3mm) minimum clearance to adjacent cabinet

doors/drawers.

4. Not approved in a stack configuration.

5. See the Combination Installation (CI) Section if

installing with a microwave, cooktop, or downdraft.

091605

1/2