Aervoe Solar Link 240 User Manual

Page 3

Advertising
background image

Section 3

CHARGING

For maximum efficiency charge after each use or every 2 months if it is being stored.

Failure to properly charge as listed below could damage the unit and affect performance.

Charging Meter - indicates charging rate

1. Five orange LEDs represent the charging rate when using any of the methods of charging below.

2. Each LED equals approximately 20% charge rate. This will help you to position a solar panel

in the best angle to the sun. If the Solar Link is plugged into a 120V or 12V power source, all 5

LEDs should be illuminated.

Battery Meter - indicates how full the battery is

1. Five blue LEDs represents the current battery capacity.

2. Each LED represents approximately 20% full.

Solar Charging

(recommended #9580 80-Watt Solar Collector)

1. The Solar Link has built-in battery protection and does not require a solar charge controller.

2. Place the Solar Link and Solar Collector in direct sun.

3. Connect the SOLAR CHARGING CABLE (included) male pin tip to the DC INPUT on the Solar

Link. Connect the MC4 (+) and (-) tips to the solar collector.

4. Adjust the Solar Panel so that it is directly facing the sun. Charging will begin immediately and

the orange CHARGING METER indicators will illuminate.

5. To ensure full battery charge, continue charging for 1 additional hour.

6. Disconnect when charging is complete.

120V AC Wall Charging

(adapter included)

The Solar Link utilizes a modified sine wave inverter. Refer to information below.

1. Connect the male pin tip of the 120V AC CHARGER into the DC IN PORT of the Solar Link and

then plug the other end into an electrical outlet.

2. The charging indicator on the 120V AC CHARGER will illuminate red when charging is in process

and green when the Solar Link has reached a full charge.

3. The CHARGING METER indicators will also illuminate.

4. To ensure full battery charge, continue charging for 1 additional hour.

5. Disconnect when charging is complete.

Modified Sine Wave Inverter Information

Modified side wave inverters are the most common type on the market and work well for

most uses. It is designed for use with small electronic equipment up to the power limits

stated - 400W.

Due to the nature of the electrical output from this inverter, some devices using variable

speed controllers and solid-state power will require the use of a Pure Sine Wave inverter

(found in the Solar Link 1000). You may notice additional noise from audio equipment or

devices with electric motors.

Unsuitable Devices

Use of any of the following items with Solar Link 240 is at the user’s own risk and Aervoe

Industries, Inc. does not accept any responsibility for damage or injury resulting from use.

Fluorescent lights with electronic ballasts

Power tools with solid state power or variable speed control

Digital clocks with radios

Sewing machines with speed/microprocessor control

X-10 home automation systems

Medical equipment such as oxygen concentrators

12V DC Vehicle Charging

(adapter included)

CAUTION: The vehicle engine must be operating to maintain the proper vehicle battery level required

to charge the Solar Link. Vehicle battery discharge or slow charging to the Solar Link could occur.

1. Connect the male pin tip of the 12V DC CHARGER into the DC IN PORT of the Solar Link and

then plug the other end into a vehicle power outlet.

2. The green charging indicator on the 12V AC CHARGER will illuminate when charging is in

process.

3. The CHARGING METER indicators will also illuminate.

4. To ensure full battery charge, continue charging for 1 additional hour.

5. Disconnect when charging is complete.

Section 4

OPERATING INSTRUCTIONS

Once charged, the Solar Link 240 is ready to use right out of the box. No set up is required. All

outputs may be used simultaneously. Check your device’s specifications to make sure they are

compatible with the Solar Link.

ON/OFF Button

- when on, the surrounding LED lights will turn green

120V AC Power Button -

when on, the surrounding LED lights will turn red

USB 2.0 Operation

Turn the ON/OFF BUTTON on

Plug in your device’s USB power or charging cable

A combined 5V/2A maximum output is available between the two ports

Disconnect and power off when not in use

120V AC Operation (max 400W output)

Turn on the 120V ON/OFF BUTTON

PRESS THE 120V AC POWER BUTTON to activate the inverter

Plug in your 120V device’s power or charging cable into the electrical socket

Disconnect and power off when not in use

12V DC Operation (Max 20A output)

Plug in your 12V device’s power or charging cable into the 12V Vehicle Socket

Neither POWER BUTTON need to be on

Disconnect and power off when not in use

Section 5

CARE & MAINTENANCE

Dust regularly with a clean dry cloth to prevent dust and dirt from building up on the

vents and power inputs/outputs

Store in a clean, dry place when not in use

Charge after each use, every 30-60 days, and before storing so it is ready to use when

needed

Advertising