Freightliner refrigerator troubleshooting guide – Dometic 750000005 (TJ18F) User Manual

Page 7

Advertising
background image

Freightliner Refrigerator Troubleshooting Guide

750000005 (TJ18F)

750000011 (TJ22F)
750000026 (TJ18FP3)


DOMETIC CORPORATION, ENVIRONMENTAL DIVISION
P.O. Box 15299 I Richmond, VA 23227 USA
Phone +804 746 1313 | Fax +804 746 7248

www.dometic.com

Page 7 of 20

Change DanFoss Module. Isolate unit from its source of energy by disconnecting the
power before performing the following procedure:

A. Remove all wires from compressor module and load dump (make note where

they are connected).

B. Removed Danfoss module from the compressor by removing the mounting screw
and twisting the module to the rear to disconnect it from the compressor.


C. Use screw driver to pry connector from compressor terminals. Use caution.

D. If changing the Danfoss module does not fix the problem, this may indicate the
compressor is bad.





Advertising