Dacor EO User Manual

Eo, po, mov & moh, Planning guide, 27, 30” wide, single, discovery wall ovens

Advertising
background image

PLANNING

GUIDE

Web: http://www.Dacor.com

Corporate Phone: 800-793-0093

Specifications are subject to change without notice.

See installation instructions for additional details.

1.9

27, 30” Wide, Single,

Discovery Wall Ovens

EO, PO, MOV & MOH

NOTES:

1. 24” (610mm) minimum interior cabinet depth.

Back of cabinet may need to be removed.

2. 3/4” (19mm) support platform (flush with cutout).

1/2

CUTOUT DIMENSIONS

“C”

“A”

“B”

31 1/4” (794mm)

Recommended

(May be Altered)

1 ¾“ (45mm) Min.

Clear to Top of

Door for Heat

Exhaust

4“ Typical Toe Kick (Shown)

Recommended

Electrical

Location

Alternate

Electrical

Location

3/4” (19mm)

Support Platform

1“ (25mm) Min.

Clear to Top of

Door for Heat

Exhaust

CUTOUT DIMENSIONS

INSTALLED UNDER-COUNTER

36” Typical

(914mm)

1 1/2”

(38mm)

Typical Counter

“A”

“B”

1 ¾“ (45mm) Min.

to Combustible Floor

4“ Typical Toe Kick (Shown)

Recommended

Electrical

Location

3/4” (19mm)

Support Platform

1“ (25mm) Min. to Combustibles

Model

Number

Cutout

Height

“A”

Cutout

Width

“B”

Min. Cabinet

Width

“C”

EO127

27 7/16”

(697mm)

25 1/2”

(648mm)

27”

(686mm)

PO127
MOV127
MOH127
EO130

28 1/2”

(724mm)

30”

(762mm)

PO130
MOV130
MOH130

3. 1/8” (3mm) minimum clearance from appliance to

adjacent cabinet doors/drawers.

4. Two (2) Single Ovens are not approved in a stack

configuration.

1 ¾” (45mm) Min.

to Combustible Floor

“A”

“B”

“A”

“B”

1 1/2” (38mm)

Typical Counter

4“ Typical Toe Kick (Shown)

Alternate

Electrical

Locations

3/4” (19mm)

Support Platform

4“ (102mm) Min.

Between Cutout

3/4” (19mm)

Support Platform

Recommended Electrical Location

1“ (25mm) Min. to Combustibles

36” (914mm)

Typical

CUTOUT DIMENSIONS

SIDE-BY-SIDE

INSTALLED UNDER-COUNTER

Revised

10/22/07

Advertising